ULTRASHINE Panther 1 Alcohol Breath Tester with Inbuilt Printer

₹46,000.00

Police use alcohol tester Panther-1 Product Features Quick and Precise Analysis: 32bit embedded processor secures high performance of the system. UK made Electrochemical/Fuel cell sensor: Highly…

Description

Police use alcohol tester Panther-1

Product Features

  1. Quick and Precise Analysis: 32bit embedded processor secures high performance of the system.
  2. UK made Electrochemical/Fuel cell sensor: Highly specificity to alcohol, unaffected by other possible breath contaminants.
  3. Compact Gas Circuit Design and Advanced Analysis process: Assure fast, accurate and stable testing results.
  4. Built-in Printer: Fast printing process and clear print-outs. Can be detached from main body and be replaced by a piece of spare lithium-ion cell.
  5. Color LCD Touch Screen: 2.8 inch 320*240 dot matrix screen provides intuitive operation.
  6. Safe & Easy to Use: All measurement functions are controlled via a single key, while menu navigation is by three menu keys
  7. Memory Capacity: Data storage of 40,000 test results. Any test results can be easily recalled, printed or downloaded to a computer for statistical analysis and back up.

Technical Data

Details Technical Data
Principle of measurement Electrochemical Sensor, alcohol-specific
Measurement Range (BrAC) 0.000mg/L~2.000mg/L
Resolution 0.001 mg/L
Accuracy:
Max. Measuring error, in relation to the ethanol standard
Ethanol Vapor Concentration
C /(mg/L)
Deviation
C<0.400 ±0.020mg/L
0.400≤C<1.000 ±5%
C≥1.000 ±20%
Calibration Every 6 months
Temperature range- operation -10°C~45°C
Temperature range-storage -30°C~70°C
Optimum Storage Conditions Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPa
No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device
Blowing Time 3 seconds (breath flow:≥20L/min)
Warm-up Time 6 seconds after switching on
Recovery Time 1-5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Display 2.8 inch color touch screen
Memory Capacity Stores 40,000 measured values with date and time
(data can be transferred to a PC or printer)
Communication Method for Printer Bluetooth
Printer Micro Thermal printer
Dimensions(L x W x H) Approx. 182mm×80mm×34mm
Number of Measurements per Battery Pack More than 500 times (under ambient conditions)
Operation Voltage State of charging State of operation
DC10~14V DC 6.3~8.4V
Batteries 2000mAh/7.4V Lithium-ion-battery
Weight Approx. 450g(including printer, batteries, paper roll)

Specifications

Application Type Law Enforcement
Type Handheld
Brand ULTRASHINE
Sensor Type Electrochemical
Model Name Panther-1
Warning Signal Beep
Mouthpiece Type Replaceable
Type Of Testing Machines Breath Analysers
Measurement Mode Active and Passive Mode
Packaging Type Box
Portability Handheld
Accuracy ± 5 %
Color Silver
Usage/Application Law Enforcement Agencies
Display Type Digital
Display 2.8 inch color touch screen
Certification ISO 9001
Type Of Mouthpiece Replaceable
Detection Range 0.50 mg/L (0.10 % BAC)
Analyzing Time 4 s
Grade Semi Automatic
Power Source Rechargeable Battery
Clearing Time 6 s
Material ABS
Memory Capacity Stores 40,000 measured values with date and time(data can be transferred to a PC or printer)
Response Time 5 s
Features Built-in Printer
Application Law Enforcement/Police
Connectivity USB, RS-232
Mode of Operation Three-key Operation
Country of Origin Made in India
Details Technical Data
Principle of measurement Electrochemical Sensor, alcohol-specific
Measurement Range (BrAC) 0.000mg/L~2.000mg/L
Resolution 0.001 mg/L
Accuracy:Max. Measuring error, in relation to the ethanol standard Ethanol Vapor Concentration C /(mg/L)
C<0.400 ±0.020mg/L
0.400≤C<1.000 ±5%
C≥1.000 ±20%
Calibration Every 6 months
Temperature range- operation -10°C~45°C
Temperature range-storage -30°C~70°C
Optimum Storage Conditions Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPaNo vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device
Blowing Time 3 seconds (breath flow:≥20L/min)
Warm-up Time 6 seconds after switching on
Recovery Time 1-5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Communication Method for Printer Bluetooth
Printer Micro Thermal printer
Dimensions(L x W x H) Approx. 182mm×80mm×34mm
Number of Measurements per Battery Pack More than 500 times (under ambient conditions)
Operation Voltage State of charging
DC10~14V DC 6.3~8.4V
Batteries 2000mAh/7.4V Lithium-ion-battery
Weight Approx. 450g(including printer, batteries, paper roll)
Minimum order quantity 1 Piece

Additional information

Application Type

Law Enforcement

Type

Handheld

Brand

ULTRASHINE

Sensor Type

Electrochemical

Model Name

Panther-1

Warning Signal

Beep

Mouthpiece Type

Replaceable

Type Of Testing Machines

Breath Analysers

Measurement Mode

Active and Passive Mode

Packaging Type

Box

Portability

Handheld

Accuracy

± 5 %

Color

Silver

Usage/Application

Law Enforcement Agencies

Display Type

Digital

Display

2.8 inch color touch screen

Certification

ISO 9001

Type Of Mouthpiece

Replaceable

Detection Range

0.50 mg/L (0.10 % BAC)

Analyzing Time

4 s

Grade

Semi Automatic

Power Source

Rechargeable Battery

Clearing Time

6 s

Material

ABS

Memory Capacity

Stores 40,000 measured values with date and time(data can be transferred to a PC or printer)

Response Time

5 s

Features

Built-in Printer

Application

Law Enforcement/Police

Connectivity

USB, RS-232

Mode of Operation

Three-key Operation

Country of Origin

Made in India

Details

Technical Data

Principle of measurement

Electrochemical Sensor, alcohol-specific

Measurement Range (BrAC)

0.000mg/L~2.000mg/L

Resolution

0.001 mg/L

Accuracy:Max. Measuring error, in relation to the ethanol standard

Ethanol Vapor Concentration C /(mg/L)

C<0.400

±0.020mg/L

0.400≤C<1.000

±5%

C≥1.000

±20%

Calibration

Every 6 months

Temperature range- operation

-10°C~45°C

Temperature range-storage

-30°C~70°C

Optimum Storage Conditions

Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPaNo vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device

Blowing Time

3 seconds (breath flow:≥20L/min)

Warm-up Time

6 seconds after switching on

Recovery Time

1-5 minutes, depends on Ethanol Vapor Concentration

Analysis Time

Less than 10 seconds

Communication Method for Printer

Bluetooth

Printer

Micro Thermal printer

Dimensions(L x W x H)

Approx. 182mm×80mm×34mm

Number of Measurements per Battery Pack

More than 500 times (under ambient conditions)

Operation Voltage

State of charging

DC10~14V

DC 6.3~8.4V

Batteries

2000mAh/7.4V Lithium-ion-battery

Weight

Approx. 450g(including printer, batteries, paper roll)

Minimum order quantity

1 Piece

Reviews

There are no reviews yet.

Be the first to review “ULTRASHINE Panther 1 Alcohol Breath Tester with Inbuilt Printer”

Your email address will not be published. Required fields are marked *