ULTRASHINE Alcohol Breath Analyser Inbuilt Printer Aviation Grade Model -KT 4000P

₹58,000.00

Alcohol Breath Analyser Inbuilt Printer- KT4000P Breath alcohol analyzer is the first and most classic alcohol tester designed for police use at the roadside to test drivers for drunk driving. More…

Description

Alcohol Breath Analyser Inbuilt Printer- KT4000P

Breath alcohol analyzer is the first and most classic alcohol tester designed for police use at the roadside to test drivers for drunk driving. More than 10 years of use provies its stability and practicability.

Product Features

  1. Quick and Precise Analysis: 32bit embedded processor secures high performance of the system.
  2. UK made Electrochemical/Fuel cell sensor: Highly specificity to alcohol, unaffected by other possible breath contaminants.
  3. Compact Gas Circuit Design and Advanced Analysis process: Assure fast, accurate and stable testing results.
  4. Built-in Printer: Fast printing process and clear print-outs. Can be detached from main body and be replaced by a piece of spare lithium-ion cell.
  5. Color LCD Touch Screen: 2.8 inch 320*240 dot matrix screen provides intuitive operation.
  6. Safe & Easy to Use: All measurement functions are controlled via a single key, while menu navigation is by three menu keys
  7. Memory Capacity: Data storage of 40,000 test results. Any test results can be easily recalled, printed or downloaded to a computer for statistical analysis and back up.
  8. Built-in GPS Function: Satellite positioning of inspection location.(Optional)
  9. Mouthpiece: Specially designed one-way mouthpiece.

Technical Data

Details Technical Data
Principle of measurement Electrochemical Sensor, alcohol-specific
Measurement Range (BrAC) 0.000mg/L~2.000mg/L
Resolution 0.001 mg/L
Accuracy:
Max. Measuring error, in relation to the ethanol standard
Ethanol Vapor Concentration
C /(mg/L)
Deviation
C<0.400 ±0.020mg/L
0.400≤C<1.000 ±5%
C≥1.000 ±20%
Calibration Every 6 months
Temperature range- operation -10°C~45°C
Temperature range-storage -30°C~70°C
Optimum Storage Conditions Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPa
No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device
Blowing Time 3 seconds (breath flow:≥20L/min)
Warm-up Time 6 seconds after switching on
Recovery Time 1-5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Display 2.8 inch color touch screen
Memory Capacity Stores 40,000 measured values with date and time
(data can be transferred to a PC or printer)
Communication Method for Printer Bluetooth
Printer Micro Thermal printer
Dimensions(L x W x H) Approx. 182mm×80mm×34mm
Number of Measurements per Battery Pack More than 500 times (under ambient conditions)

Specifications

Application Type Law Enforcement
Type Handheld
Brand ULTRASHINE
Sensor Type Electrochemical
Model Name KT-4000P
Mouthpiece Type Replaceable
Type Of Testing Machines Alcohol Breath Analyser
Warning Signal Beep
Measurement Mode Active and Passive Mode
Portability Handheld
Packaging Type Box
Accuracy 95 %
Color Silver
Instrument Name Breath Analyser
Usage/Application Law Enforcement Agencies
Model Name/Number KT4000P
Display Type Digital
Parameters Blood Alcohol Content
Automation Semi Automatic
Certification ISO 9001
Display 2.8 inch color touch screen
User Input Touch
Detection Range 0.50 mg/L (0.10 % BAC)
Printer Micro Thermal printer
Power Source Rechargeable Battery
Substance Tested Alcohol
Grade Semi Automatic
Sample Type Breath
Memory Capacity Stores 40,000 measured values with date and time(data can be transferred to a PC or printer)
Power Supply Charger AC
Response Time 5 s
Features Built-in Printer
Application Industrial / Workplace
Connectivity RS-232, USB
Mode of Operation Three-key Operation
Details Technical Data
Principle of measurement Electrochemical Sensor, alcohol-specific
Measurement Range (BrAC) 0.000mg/L~2.000mg/L
Resolution 0.001 mg/L
Accuracy:Max. Measuring error, in relation to the ethanol standard Ethanol Vapor Concentration C /(mg/L)
C<0.400 ±0.020mg/L
0.400≤C<1.000 ±5%
C≥1.000 ±20%
Calibration Every 6 months
Temperature range- operation -10°C~45°C
Temperature range-storage -30°C~70°C
Optimum Storage Conditions Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPaNo vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device
Blowing Time 3 seconds (breath flow:≥20L/min)
Warm-up Time 6 seconds after switching on
Recovery Time 1-5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Communication Method for Printer Bluetooth
Dimensions(L x W x H) Approx. 182mm×80mm×34mm
Number of Measurements per Battery Pack More than 500 times (under ambient conditions)
Minimum order quantity 1 Piece

Additional information

Application Type

Law Enforcement

Type

Handheld

Brand

ULTRASHINE

Sensor Type

Electrochemical

Model Name

KT-4000P

Mouthpiece Type

Replaceable

Type Of Testing Machines

Alcohol Breath Analyser

Warning Signal

Beep

Measurement Mode

Active and Passive Mode

Portability

Handheld

Packaging Type

Box

Accuracy

95 %

Color

Silver

Instrument Name

Breath Analyser

Usage/Application

Law Enforcement Agencies

Model Name/Number

KT4000P

Display Type

Digital

Parameters

Blood Alcohol Content

Automation

Semi Automatic

Certification

ISO 9001

Display

2.8 inch color touch screen

User Input

Touch

Detection Range

0.50 mg/L (0.10 % BAC)

Printer

Micro Thermal printer

Power Source

Rechargeable Battery

Substance Tested

Alcohol

Grade

Semi Automatic

Sample Type

Breath

Memory Capacity

Stores 40,000 measured values with date and time(data can be transferred to a PC or printer)

Power Supply

Charger AC

Response Time

5 s

Features

Built-in Printer

Application

Industrial / Workplace

Connectivity

RS-232, USB

Mode of Operation

Three-key Operation

Details

Technical Data

Principle of measurement

Electrochemical Sensor, alcohol-specific

Measurement Range (BrAC)

0.000mg/L~2.000mg/L

Resolution

0.001 mg/L

Accuracy:Max. Measuring error, in relation to the ethanol standard

Ethanol Vapor Concentration C /(mg/L)

C<0.400

±0.020mg/L

0.400≤C<1.000

±5%

C≥1.000

±20%

Calibration

Every 6 months

Temperature range- operation

-10°C~45°C

Temperature range-storage

-30°C~70°C

Optimum Storage Conditions

Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPaNo vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device

Blowing Time

3 seconds (breath flow:≥20L/min)

Warm-up Time

6 seconds after switching on

Recovery Time

1-5 minutes, depends on Ethanol Vapor Concentration

Analysis Time

Less than 10 seconds

Communication Method for Printer

Bluetooth

Dimensions(L x W x H)

Approx. 182mm×80mm×34mm

Number of Measurements per Battery Pack

More than 500 times (under ambient conditions)

Minimum order quantity

1 Piece

Reviews

There are no reviews yet.

Be the first to review “ULTRASHINE Alcohol Breath Analyser Inbuilt Printer Aviation Grade Model -KT 4000P”

Your email address will not be published. Required fields are marked *