ULTRASHINE Digital Alcohol Breath Analyzer KT8300

₹18,900.00

Alcohol Breath Anlyser (Printer Optionally) KT8300P Product Desription: 1. Quick and Precise Analysis: 32-bit embedded processor secures high performance of the system. 2. UK made…

Description

Alcohol Breath Anlyser (Printer Optionally) KT8300P

Product Desription :

1. Quick and Precise Analysis: 32-bit embedded processor secures high performance of the system.

2. UK made Electrochemical/Fuel cell Sensor: Highly specificity to alcohol, unaffected by other possible breath contaminants.

3. Data Handling Ability: Compact gas circuit design and advanced analysis process assure fast, accurate and stable testing performance.

4. Active and Passive Blow Methods: Both methods can be applied to provide convenience to the user.

5. Memory Capacity: Data storage of 20000 test results. Any test results can be downloaded to the computer for data backup.

Details Technical data
Principle of measurements Electrochemical/fuel cell sensor, alcohol specific
Measurement range (BrAC) 0.000mg/L~1.500mg/L
Resolution 0.0001 mg/L
Accuracy: Max. Measure error, in relation to ethanol standard Ethanol Vapor ConcentrationC /(mg/L) Deviation
C<0.400 ±0.020mg/L
0.400≤C<1.000 ±5%
C≥1.000 ±20%
Repeatability of Indicating Value Ethanol Vapor ConcentrationC /(mg/L) Deviation
C<0.400 0.007mg/L
0.400≤C<1.000 1.75%
C≥1.000 6%
Calibration Every 6 months
Temperature Range-Operation -10℃~45℃
Temperature Range-Storage -20℃~70℃
Optimum Storage Condition Temperature 20℃±5, Humidity: <80%RH, Pressure: 86kPa~106kPa, No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device.
Blowing Time 2.5 seconds (breath flow≥20L/min)
Warm-up Time Less than 5 seconds after switching on
Recovery Time 5 seconds to 5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Display 128×64 dot matrix black and white screen
Dimensions Approx. 127mm×60mm×28mm
Memory 4096 records
Operation Voltage State of Charging State of Operation
5 V DC 3.6~4.2V
Battery Built-in 1000mAh/3.7V Li-ion polymerized battery
Weight Approx. 115g (including batteries)

Specifications

Application Type Industrial
Type Handheld
Sensor Type Advanced Fuel Cell
Brand ULTRASHINE
Model Name KT-8300
Warning Signal Beep
Mouthpiece Type Replaceable
Measurement Mode Active Sampling
Packaging Type Box
Portability Portable
Accuracy ± 5 %
Color Black
Instrument Name Breath Analyser
Display Type Digital
Usage/Application Hospital
Parameters Blood Alcohol Content
Automation Semi Automatic
Display 128×64 dot matrix black and white screen
Type Of Mouthpiece Replaceable
Grade Semi-Automatic
Material ABS
Country of Origin Made in India
Details Technical data
Principle of measurements Electrochemical/fuel cell sensor, alcohol specific
Measurement range (BrAC) 0.000mg/L~1.500mg/L
Resolution 0.0001 mg/L
Accuracy: Max. Measure error, in relation to ethanol standard Ethanol Vapor ConcentrationC /(mg/L)
C<0.400 0.007mg/L
0.400≤C<1.000 1.75%
C≥1.000 6%
Repeatability of Indicating Value Ethanol Vapor ConcentrationC /(mg/L)
Calibration Every 6 months
Temperature Range-Operation -10℃~45℃
Temperature Range-Storage -20℃~70℃
Optimum Storage Condition Temperature 20℃±5, Humidity: <80%RH, Pressure: 86kPa~106kPa, No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device.
Blowing Time 2.5 seconds (breath flow≥20L/min)
Warm-up Time Less than 5 seconds after switching on
Recovery Time 5 seconds to 5 minutes, depends on Ethanol Vapor Concentration
Analysis Time Less than 10 seconds
Dimensions Approx. 127mm×60mm×28mm
Memory 4096 records
Operation Voltage State of Charging
5 V DC 3.6~4.2V
Battery Built-in 1000mAh/3.7V Li-ion polymerized battery
Weight Approx. 115g (including batteries)
Minimum order quantity 2 Piece

Additional information

Application Type

Industrial

Type

Handheld

Sensor Type

Advanced Fuel Cell

Brand

ULTRASHINE

Model Name

KT-8300

Warning Signal

Beep

Mouthpiece Type

Replaceable

Measurement Mode

Active Sampling

Packaging Type

Box

Portability

Portable

Accuracy

± 5 %

Color

Black

Instrument Name

Breath Analyser

Display Type

Digital

Usage/Application

Hospital

Parameters

Blood Alcohol Content

Automation

Semi Automatic

Display

128×64 dot matrix black and white screen

Type Of Mouthpiece

Replaceable

Grade

Semi-Automatic

Material

ABS

Country of Origin

Made in India

Details

Technical data

Principle of measurements

Electrochemical/fuel cell sensor, alcohol specific

Measurement range (BrAC)

0.000mg/L~1.500mg/L

Resolution

0.0001 mg/L

Accuracy: Max. Measure error, in relation to ethanol standard

Ethanol Vapor ConcentrationC /(mg/L)

C<0.400

0.007mg/L

0.400≤C<1.000

1.75%

C≥1.000

6%

Repeatability of Indicating Value

Ethanol Vapor ConcentrationC /(mg/L)

Calibration

Every 6 months

Temperature Range-Operation

-10℃~45℃

Temperature Range-Storage

-20℃~70℃

Optimum Storage Condition

Temperature 20℃±5, Humidity: <80%RH, Pressure: 86kPa~106kPa, No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device.

Blowing Time

2.5 seconds (breath flow≥20L/min)

Warm-up Time

Less than 5 seconds after switching on

Recovery Time

5 seconds to 5 minutes, depends on Ethanol Vapor Concentration

Analysis Time

Less than 10 seconds

Dimensions

Approx. 127mm×60mm×28mm

Memory

4096 records

Operation Voltage

State of Charging

5 V

DC 3.6~4.2V

Battery

Built-in 1000mAh/3.7V Li-ion polymerized battery

Weight

Approx. 115g (including batteries)

Minimum order quantity

2 Piece

Reviews

There are no reviews yet.

Be the first to review “ULTRASHINE Digital Alcohol Breath Analyzer KT8300”